Vaporizer sizing for LNG and cryogenic installations

Correctly sizing a vaporizer is crucial for the reliability and efficiency of LNG and cryogenic installations. In practice, vaporizers are often designed based solely on maximum flow rate. This regularly leads to performance problems or unnecessarily high investment costs. Effective vaporizer sizing requires a broader, operationally driven approach.


Why maximum flow is not enough

When vaporizer capacity is based solely on peak load, risks such as ice formation, unstable outlet temperatures, and trips during periods of high demand arise. On the other hand, oversizing leads to higher CAPEX and reduced controllability at low loads. A good design balances capacity, availability, and operational flexibility.


Designing based on demand profiles

Proper vaporizer sizing starts with an understanding of the actual use of the installation. This involves looking at hourly and daily consumption, load and start-up scenarios, and possible future expansions. The actual demand profile, not the nameplate data, forms the basis for the design.


Distinction between average load and peaks

For a robust capacity calculation, it is essential to distinguish between average flow, structural peak load, and short-term transients. The average load mainly determines energy consumption and operating costs. Structural peaks determine the required vaporizer capacity, while very short peaks can often be better accommodated with buffering or smart process control rather than additional heat exchange surface.


Icing derating and climate influences

In atmospheric vaporizers, ice formation has a direct impact on heat transfer and temperature stability. Without realistic icing derating, a vaporizer may appear to be sufficiently large in theory, but in practice, undercapacity will occur. In addition, design conditions must be based on the most unfavorable seasonal situation, usually winter conditions with low ambient temperatures and limited humidity.


Redundancy, availability, and turndown

The desired availability of the LNG or cryogenic installation determines the degree of redundancy. Choices for N, N+1, or partial standby configurations are made based on security of supply, contractual obligations, and the costs of downtime. At the same time, turndown is important: an oversized vaporizer can cause instability at low loads. Modular vaporizer setups with intelligent control ensure stable performance across the entire capacity range.


Exhaust temperature as a critical design parameter

The required exhaust temperature often determines the overall vaporizer design. Stricter temperature specifications require more heat exchange surface area, additional redundancy, and higher investments. Establishing this requirement early on prevents costly modifications at a later stage.


Conclusion: vaporizer sizing as a design method

Vaporizer sizing is not a single calculation, but a coherent design methodology that combines process conditions, climate, operational management, and availability. A well-dimensioned vaporizer delivers stable performance, high availability, and an optimal cost profile over the lifetime of the installation.


This approach is in line with Cryonorm's engineering vision, where vaporizer design is always tailored to the entire process context and the operational reality of LNG and cryogenic installations.